Allwyn Solar Cables xlpo uv pvc
A. Type 1 HR-UV PVC (IS 694)

Construction

Conductor:Stranded tinned and bare copper wire
Insulation:UV grade PVC
Sheath:UV grade PVC
Colors:Black & Red, others on request

Application

Solar cable is the interconnection cable used in photovoltaic power generation. A solar cable interconnects solar panels and other electrical components of a photovoltaic system. Solar cables are designed to be UV resistant and weather resistant.

Special features

  • Weather/UV-resistant acc. to HD 605/A1
  • Ozone-resistant according to EN 50396
  • Halogen-free and flame-retardant
  • Good notch and abrasion resistance

Type 1 HR-UV PVC (IS 694)

Size of Cable (sqmm)Max. Conductor D.C. Resistance at 20°C in ohm/ (km)Average Diameter Of Conductor (in mm)Approx. Overall Diameter Of Cable (in mm)Approximate Overall Weight (in kg/km)Minimum Bending Radius (in mm)Current Rating Under Continuous Operation 90°C And Ambient Temperature 40°C (in A)
1.513.71.464.464.86351922
2.58.211.884.885.28462130
45.092.395.395.79642342
63.392.935.936.33842552
101.953.867.267.661333176
161.245.398.799.191953795
250.7956.7310.5311.1329045124
350.5658.0811.8812.4839050159
500.3939.6913.4914.0953056185
700.27711.5415.3415.9471564239
  • The number of wires is approximate and wire diameter is nominal. They shall be such as to satisfy the requirements of conductor resistance.
  • In view of continuous improvements in our design and process, specifications given here in are subject change without prior notice.
B. Type 2 XLPO sheathed and insulated (TÜV 2Pfg1169/08.2007)

Construction

Conductor:Tinned copper conductors of class 5
Insulation:XLPO 120˚C
Sheath:Special grade XLPO
Colors:Black & Red, others on request

Application

Solar cable is the interconnection cable used in photovoltaic power generation. A solar cable interconnects solar panels and other electrical components of a photovoltaic system. Solar cables are designed to be UV resistant and weather resistant.

Special features

  • As per TÜV 2Pfg1169/08.2007
  • UV, ozone-resistant, weather-resistant,
  • Halogen-free
  • Abrasion and cut resistant
  • Relatively flexible
  • Easy to strip
  • Flame-resistant according to VDE 0482 Part 332-1-2, IEC 60332-1-2
  • Anticipated service life 25 years

Type 2 XLPO sheathed and insulated

Number & Nominal Cross sectional area of conductor (mm)No. of Cu strands/max diameter of cu strandNominal dia. Over bunched conductorNominal Insulation thickness (mm)Nominal Sheath thickness (mm)Nominal Overall Diameter (mm)Max. Conductor (ATC) resistance at 20*C (Ω/Km)Current carrying capacity at 60C
Single cable in air
1.5030/0.251.400.70.84.8+/-0.513.724
2.5050/0.251.900.70.85.2+/-0.58.2141
4.0056/0.302.400.70.85.7+/-0.55.0955
6.0084/0.303.150.70.86.5+/-0.53.3970
10.0080/0.404.200.80.98.2+/-0.51.9598
16.00127/0.405.200.80.99.4+/-0.61.24132
25.00200/0.406.801.01.011.5+/-0.80.795176
35.00280/0.407.801.01.112.6+/-1.00.565218
50.00400/0.409.801.11.215.0+/-1.00.393276

Derating factor for cables

AIR TEMPERATUREUPTO 60708090100110
DE-RATING FACTOR1.000.910.820.710.580.41
  • The number of wires is approximate and wire diameter is nominal. They shall be such as to satisfy the requirements of conductor resistance.
  • In view of continuous improvements in our design and process, specifications given here in are subject change without prior notice.

Specifications given here are subject to change to satisfy requirements. The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance.